產品名稱:Mikro-Tip Pressure Transducer Catheters
產品編號:Mikro-Tip Pressure Transducer Catheters
廠  牌:Millar Instruments, Inc.

Millar Mikro-TipR pressure intravascular catheters provide a simple, efficient and highly accurate method of measuring pressures in the heart or cardiovascular system. These reusable, thromboresistant Mikro-Tip catheters are ideal for high fidelity pressure measurement. Standard catheters range in size from 2 to 7 French and in length up to 140 cm.

Single Pressure Sensor
Single Pressure Sensor With Lumen
Dual Pressure Sensor
Dual Pressure Sensor With Lumen

   
Analyze your pressure data with our new software
   

Download Brochure

 

Single Pressure Sensor

The following tables list the single pressure sensor models:

  MPR-500 * SPR-320 * SPR-330A SPR-340 SPR-340S
Part Number 840-8162 840-8160 840-8164 840-8165 840-8165-1
Catheter Material Polyurethane Polyurethane Nylon Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Effective Length 70 cm 140 cm 130 cm 120 cm 120 cm
French Size 5 2 3 4 4
Number of Sensors 1 1 1 1 1
Sensor Location from Tip Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Tip Characteristics Straight Straight Straight Curved Straight
Connector Type Viking Viking Viking Viking Viking
Reusable Yes Yes Yes Yes Yes
Repairable No Yes Yes Yes Yes

* Click to link for specific model photo and information
NOTE: Viking connectors are round with 4 pins

NOTE: The MPR-500 is a thromboresistant, low-cost reusable catheter designed for intraoperative placement. It can be used for post open-heart pressure monitoring. The MPR-500 provides accurate high fidelity pressure monitoring with no damping or danger of air embolism. The MPR-500 is non-repairable and warranted for 30 days against defects in materials and workmanship.

  SPR-350 * SPR-350S * SPR-360 SPR-360S SPR-370 SPR-370S
Part Number 840-8166 840-8166-1 840-8167 840-8167-1 840-8168 840-8168-1
Catheter Material Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Effective Length 120 cm 120 cm 120 cm 120 cm 120 cm 120 cm
French Size 5 5 6 6 7 7
Number of Sensors 1 1 1 1 1 1
Sensor Location from Tip Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Tip Characteristics Curved Straight Curved Straight Curved Straight
Connector Type Viking Viking Viking Viking Viking Viking
Reusable Yes Yes Yes Yes Yes Yes
Repairable Yes Yes Yes Yes Yes Yes

* Click to link for specific model photo and information
NOTE: Viking connectors are round with 4 pins

Single Pressure Sensor With Lumen

Slow-Speed Injection and Sampling
Approved for Human Use. Millar manufactures and markets a line of Mikro-Tip pressure catheters with a lumen for fluid sampling or slow-speed injection; all are available in sizes from 5 to 7 French.

High-Speed Injection
Millar manufactures and markets two models of single sensor catheters for high-speed injection. The lumen has two laterally opposed side openings on the SPR-471A. The SPR-474A has an open-end pigtail extension for use with a .032 inch (.8 mm) guide wire. Typical injections rates of radiopaque contrast dye (Renografin 76) at 1200 psi (8274 kPa) are 10 to 15 ml/sec. The SPR-471A injection lumen side openings are located 1 cm from the tip, and the model SPR-474A injection lumen is located 1 cm from the pigtail attachment.

The following table lists the single pressure sensor with lumen models:

  SPR-450 * SPR-450S SPR-470 SPR-471A * SPR-474A *
Part Number 840-8169 840-8169-1 840-8170 840-8171 840-8172
Catheter Material Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Effective Length 120 cm 120 cm 120 cm 115 cm 120 cm
French Size 5 5 7 7 7
Sensor Location from Tip Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Side mounted
at tip
Side mounted at tip,
proximal to pigtail
Tip Characteristics Curved Straight Curved Curved Straight
Lumen Type Sampling/
Slow speed injection
Sampling/
Slow speed injection
Sampling/
Slow speed injection
High speed injection High speed injection/
Guide wire
Lumen I.D. 0.4 mm 0.4 mm 0.7 mm 1.0 mm 0.9 mm
Flow Rate (H2O) 4 ml/minute
@ 1 atmosphere
4 ml/minute
@ 1 atmosphere
25 ml/minute
@ 1 atmosphere
15 ml/second
@ 1200 psi (8274 kPa)
15 ml/second
@ 1200 psi (8274 kPa)
Flow Rate Radiopaque Dye
(Renografin-76)
No No No 10-15 ml/second
@ 1000 psi (6895 kPa)
10-15 ml/second
@ 1000 psi (6895 kPa)
Guide Wire No No No No .032 inch (.8 mm)
Pigtail No No No No Yes
Connector Type Viking Viking Viking Viking Viking
Reusable Yes Yes Yes Yes Yes
Repairable Yes Yes Yes Yes Yes

* Click to link to specific model photo and information
NOTE: Viking connectors are round with 4 pins

Dual Pressure Sensor

Millar manufactures and markets a line of dual pressure sensor catheters for simultaneous high fidelity pressure measurements. These catheters are suitable for measuring pressure gradients across a valve, between chambers, or across a vascular stenosis. The catheters are made of polyurethane material (some include a woven dacron braid), are thromboresistant, and range in size from 2.5 to 7 French. The following table lists the dual pressure sensor models:

  SPR-721 *
Part Number 840-8173
Catheter Material Polyurethane
Effective Length 135 cm
French Size 2.5
Number of Sensors 2
Sensor Location from Tip First at tip,
second
5 cm proximal
Tip Characteristics Straight
Connector Type Viking
Reusable Yes
Repairable Yes

* Click to link to specific model photo and information
NOTE: Viking connectors are round with 4 pins


Dual Pressure Sensor with Lumen

These dual pressure sensor catheters incorporate a lumen for sampling/slow-speed injection, slow-speed injection/guide wire, or high-speed injection/guide wire. The model SPR-784A for high-speed injection has two laterally opposed lumen side openings and an open-end pigtail extension for use with a guide wire. The following table lists the dual pressure sensor with lumen models:
  SPR-780C * SPR-784A *
Part Number 840-8174 840-8175
Catheter Material Polyurethane/
Woven Dacron
Polyurethane/
Woven Dacron
Effective Length 120 cm 120 cm
French Size 8 8.5
Number of Sensors 2 2
Sensor Location
from Tip
First at tip,
second 5 cm back
First at tip, behind pigtail and lumen, second 5 cm back
Tip Characteristics Straight Straight
Lumen/Type Slow-speed injection/
Guide wire
High-speed injection/
Guide wire
Flow Rate (H2O) 55 ml/minute
@ 1 atmosphere
9 ml/second
@1200 psi (8274 kPa)
Flow Rate Radiopaque
Contrast Dye (Renografin-76)
No 10 ml/second
@ 1000 psi (6895 kPa)
Lumen
Inside Diameter
0.8 mm 1.1 mm
Guide Wire .032 inch .038 inch
Pigtail Yes Yes
Connector Type Viking Viking
Reusable Yes Yes
Repairable Yes Yes

* Click to link to specific model photo and information
NOTE: Viking connectors are round with 4 pins

Accessories
Millar Instruments offers a selection of Pressure Control Units and cables that interface Millar Mikro-TipR catheter pressure transducers to physiological monitors. All accessories are sold separately.

http://www.millarinstruments.com/products/cardio/cardio_sngldualauo.php

     
 
老鼠步態分析系統
ALZET1004
自動軌跡追蹤系統

  生命科學首頁 最新消息 活動快訊 產品資訊 技術支援 聯絡我們 好站連結 電子報 網站地圖  

  回國揚