產品名稱:NAN Electrode Drive System 電極調控定位裝置
產品編號:NAN Drive
廠  牌:Plexon Inc.

  • Basic components:
    • Base - The Base is the foundation of the drive. It may be round, rectangular, or have any other suitable geometric shape. The grooves on the Base allow the tower holders to be moved forward and backward while the electrode tower's ability to rotate enables circular movement. A single base accommodates between 4-25 electrode towers. The base is custom made to sit on a chamber, a stereotactic frame, a robot's arm, or any other suitable adaptation.
    • Electrode Tower - The Electrode Tower attaches to the base. Each tower includes a miniature motor coupled to a driving screw that moves a cartridge. The cartridge can be customized to hold a microelectrode, probe, needle, dagger electrode, tetrode, or a group of electrodes.

      The direct coupling of the cartridge to the motor provides reliable and accurate movement.
    Optional adapters:
    • Coarse Movement System - The Coarse Movement System (CMS) is an optional adapter when the user needs to penetrate the dura with the guiding tubes. It allows manual control in the Z direction within a user defined working depth of up to 100 mm. The adapter sits on the chamber or whatever adaptation is used.
    • XY Stage - The XY Stage is an adapter that allows smoother controlled penetration of the entire drive. The XY Stage holds the base and enables the user to manually control vertical and horizontal coarse electrode positioning in the Z direction and XY plane.

    Product Features:

    • Modular - A single drive has the capacity to handle from 1 to 16 electrodes
    • Lightweight - A basic 4-channel drive (4-channel base and 4 towers) weighs 125 grams
    • Flexible positioning - Each electrode/tetrode can be independently positioned in the XY plane, within a user defined working range
    • Precise electrode placement - 1 micron step size with minimal backlash
    • Cost-effective system - A single drive can accommodate 16 towers -- add towers as your need for more electrodes increases
    • Sophisticated control software - The user can select a subset of channels using a variety of controls
    • Uses standard, inexpensive electrodes - Customers can use almost any stiff-wire electrode; electrodes can be easily exchanged
http://www.plexoninc.com/products/nan-drive.htm

     
 