心血管研究
代謝分析
生化分析/血球計數
生理訊號紀錄
生理教學
血流血氧
其他
呼吸研究
疼痛測試
神經科學
動物行為分析
動物照護設備
細胞
透析膜
無線遙測
給藥 / 採樣
試劑 / 耗材
運動生理
電生理
實驗器械
離體灌流系統
神經科學
產品名稱:
NAN Electrode Drive System 電極調控定位裝置
產品編號:
NAN Drive
廠 牌:
Plexon Inc.
Basic components:
Base
- The Base is the foundation of the drive. It may be round, rectangular, or have any other suitable geometric shape. The grooves on the Base allow the tower holders to be moved forward and backward while the electrode tower's ability to rotate enables circular movement. A single base accommodates between 4-25 electrode towers. The base is custom made to sit on a chamber, a stereotactic frame, a robot's arm, or any other suitable adaptation.
Electrode Tower
- The Electrode Tower attaches to the base. Each tower includes a miniature motor coupled to a driving screw that moves a cartridge. The cartridge can be customized to hold a microelectrode, probe, needle, dagger electrode, tetrode, or a group of electrodes.
The direct coupling of the cartridge to the motor provides reliable and accurate movement.
Optional adapters:
Coarse Movement System
- The Coarse Movement System (CMS) is an optional adapter when the user needs to penetrate the dura with the guiding tubes. It allows manual control in the Z direction within a user defined working depth of up to 100 mm. The adapter sits on the chamber or whatever adaptation is used.
XY Stage
- The XY Stage is an adapter that allows smoother controlled penetration of the entire drive. The XY Stage holds the base and enables the user to manually control vertical and horizontal coarse electrode positioning in the Z direction and XY plane.
Product Features:
Modular -
A single drive has the capacity to handle from 1 to 16 electrodes
Lightweight
- A basic 4-channel drive (4-channel base and 4 towers) weighs 125 grams
Flexible positioning -
Each electrode/tetrode can be independently positioned in the XY plane, within a user defined working range
Precise electrode placement
- 1 micron step size with minimal backlash
Cost-effective system
- A single drive can accommodate 16 towers -- add towers as your need for more electrodes increases
Sophisticated control software
-
The user can select a subset of channels using a variety of controls
Uses standard, inexpensive electrodes -
Customers can use almost any stiff-wire electrode; electrodes can be easily exchanged
http://www.plexoninc.com/products/nan-drive.htm
生命科學首頁
最新消息
活動快訊
產品資訊
技術支援
聯絡我們
好站連結
電子報
網站地圖
回國揚