Unique ultrasonic transit time technology measures volume flow with sensors specifically designed for greatest accuracy on tubing.
SpecificationsAcousticsCalibrationOrderingMost non-aerated liquids can be measured including saline and buffer solutions, blood, water and even Diesel fuel. No physical contact is made with the fluid media. PXL-Series Flowsensors can be calibrated and programmed for up to 4 different fluid / temperature / tubing combinations and will work with most flexible tubing types. Sensor size is determined by outside diameter of the tubing.
SpecificationsAcousticsCalibrationOrdering
SENSOR SIZEME-
APPLICATIONS
FLUID TYPE
-2PXL
Infusion pumps, intravenous tubing, perfusion devices, delivery systems
cell culture, saline, buffer
-3PXL
Bioreactor tissue generation, isolated organs & vessels, perfusion devices/delivery systems, shunts
-4PXL
Experimental dialysis, bioreactor tissue generation, perfusion devices/delivery systems, isolated organs/vessels, shunts
-5PXL
-6PXL
Experimental CP Bypass, ECMO, organ perfusion
blood, water/glycerinesaline
- 7PXL
Experimental CP Bypass, ECMO
-8PXL
-9PXL
-10PXL
VAD (Ventricular Assist Device)
blood, blood analog, water/glycerine
-11PXL
blood analog, water/glycerine
-12PXL
-14PXL
-16PXL
TAH (Total Artificial Heart), VAD (Ventricular Assist Device
-20PXL
TAH (Total Artificial Heart), Mock Circulatory Systems, Heart Valve Tubing
*Note: These are typical flow rates requested and are not indicative of the maximum or minimum flow rate. Fluid types listed are typically requested and not exclusive to size.
Sterile tubing flowsensors are calibrated for the tubing fluid, temperature and typical flow rate with which the sensor will be used for the greatest accuracy. Up to four combinations are possible for each sensor.
Since fluid density and temperature alter the transit time of the ultrasound signal, the sensors are calibrated for these parameters. Sttandard calibrations include: Blood, glycerine/water solutions, saline and buffer solutions at 23 or 37 degrees C.Custom calibration for other solutions is available for extra charge. (An MSDS is required before handling the solution).
Medical grade and laboratory tubing are generally compatable for use with XL-Sensors. Rigid PVC and lucite are not. We stock several standard tubing types noted in the table below. For other tubing types, a 30 cm sample is required for sensor calibration.
Transonic Systems provides documentation for calibration traceable to NIST standards.
Probe SizeME-
Tubing (inches)
Stock Tubing
OD
ID
Wall
5/32
3/32
1/32
Tygon S-50-HL, Tygon R-3603
3/16
1/8
Tygon R-3603
1/4
1/16
Tygon R-3603, Tygon S-50-HL
5/16
3/8
MEDIFLEX, Tygon R-3603, Tygon S-50-HL
-7PXL
7/16
1/2
9/16
BENTLY BYPASS, MEDIFLEX, Tygon R-3603, Tygon S-50-HL
5/8
11/16
BENTLY BYPASS 70, Tygon R-3603, Tygon S-50-HL
3/4
7/8
1
1 1/4